Description
Delta ME300 Basic Compact Series AC Inverter for 0.4kW (1/2HP) 115V/230V 3ph motor to 2,5A at high overload or 0.4kW (1/2HP) to 2,7A when Fan/Pump rated. Operates in VxF or Sensorless Vector and converts fixed frequency Single Phase 115V input to variable frequency Three Phase to 230V to control a standard AC induction, permanent magnet motor, IPM (Interior permanent magnet) and SPM (surface mounted permanent magnet).
Input Current: 2,5A at High Overload, 2,7A when Fan/Pump rated.
Input Voltage: Single phase AC 100–120 V (-15– +10%), 50/60 Hz.
Output: Variable to 230V Three phase.
EMC Filter: None (Unfiltered)
Frame Size: A3 68mm Wide x 107mm Deep x 128mm High. IP20.
Mounting via 4 x M5 bolts (not supplied) at rear on 56mm x 118mm centres. (Optional DIN-Rail mounting available – see linked products below).
Weight: 0.5kg.
Overload:
150% for 60 seconds. High Overload. (Heavy Duty, HD), 200% of rated output current for 3 seconds.
120% for 60 seconds. Fan/Pump Rated. (Normal Duty, ND), 150% of rated output current for 3 seconds.
Speed Control Range: 0-599Hz. +/- 0.1%.
1 : 50 (V/f, SVC control for IM, heavy duty).
1 : 20 (SVC control for PM, heavy duty).
Switching (Carrier frequency): 2-15 kHz.
Braking (DBr): Built-in braking transistor for 125% Torque x 10 seconds every 100 seconds to 95 Ohm minimum external resistor (not supplied). Recommended resistor 200 Ohms 80W – see the Resistor options linked below or use the ‘Which Resistor’ button on this page. (Does not have to be used; available if required)
Product Features: Integrated Operator Keypad with integral potentiometer, (Option external keypad can be connected to the RS485 port (RJ45)) – see linked products below.
1 Analogue Input (0-10Vdc, 0-20mA & 4-20mA), 5 Programmable Digital Inputs (PNP/NPN), 1 Pulse Input (10kHz), 1 Analogue Output, 1 Digital Output,Modbus RS485 (RJ45)
1 Relay set of Changeover contacts (Resistive Load 3A/250VAC -5A/30VDC, Inductive Load 1.2A/250VAC -2A/30VDC)
Common DC Bus Terminals
Safe Torque Off (STO): Functional to SIL2 (EN61800), EN 60204-1 Category 0, EN 62061 SIL CL 2, SO 13849-1:2015 Category 3 PL d.
Environment and installation:
Pollution degree 2, Indoor use only, Cubicle mount only.
Rated at IP20
Humidity: 90%
Altitude: 0 ~ 1000m for normal operation
Heat Loss at High Overload: 27.3W total at max output
Cooling: Natural, no internal fan.
Ambient operating temperature to 50°C (40°C when units mounted side-by-side)
Ventilation space in front [not specified], above: 50mm, below: 50mm, at sides 30mm.
Certification: CE, UL, RoHS RCM, TUV, REACH, KC.