Schneider Altivar 12 0.18kW 115V 1ph to 230V 3ph AC Inverter Drive, No Filter ATV12H018F1 Repairing Services

Upgrade your power solutions with Astar’s premium Delta ME300 IP20 0.4kW 115V 1ph to 230V 3ph AC Inverter. This sleek and innovative inverter is designed to save you energy and improve the performance of your machinery. With DBr, STO, and Unfiltered VFD2A5ME11ANSAA functionalities, our AC inverter is built to give you the power you need. And if anything goes wrong, our reliable repair services have you covered. Choose Astar for all your power needs.

Contact us to inquire about this product

If you love this product and wish for a customized quote contact us at number +9190449 0777 and we will be happy to provide you with more info!

Add To Inquiry

Category:

Description

Delta ME300 Basic Compact Series AC Inverter for 0.4kW (1/2HP) 115V/230V 3ph motor to 2,5A at high overload or 0.4kW (1/2HP) to 2,7A when Fan/Pump rated. Operates in VxF or Sensorless Vector and converts fixed frequency Single Phase 115V input to variable frequency Three Phase to 230V to control a standard AC induction, permanent magnet motor, IPM (Interior permanent magnet) and SPM (surface mounted permanent magnet).

Input Current: 2,5A at High Overload, 2,7A when Fan/Pump rated.
Input Voltage: Single phase AC 100–120 V (-15– +10%), 50/60 Hz.
Output: Variable to 230V Three phase.
EMC Filter: None (Unfiltered)

Frame Size: A3 68mm Wide x 107mm Deep x 128mm High. IP20.
Mounting via 4 x M5 bolts (not supplied) at rear on 56mm x 118mm centres. (Optional DIN-Rail mounting available – see linked products below).
Weight: 0.5kg.

Overload:
150% for 60 seconds. High Overload. (Heavy Duty, HD), 200% of rated output current for 3 seconds.
120% for 60 seconds. Fan/Pump Rated. (Normal Duty, ND), 150% of rated output current for 3 seconds.

Speed Control Range: 0-599Hz. +/- 0.1%.
1 : 50 (V/f, SVC control for IM, heavy duty).
1 : 20 (SVC control for PM, heavy duty).
Switching (Carrier frequency): 2-15 kHz.

Braking (DBr): Built-in braking transistor for 125% Torque x 10 seconds every 100 seconds to 95 Ohm minimum external resistor (not supplied). Recommended resistor 200 Ohms 80W – see the Resistor options linked below or use the ‘Which Resistor’ button on this page. (Does not have to be used; available if required)

Product Features: Integrated Operator Keypad with integral potentiometer, (Option external keypad can be connected to the RS485 port (RJ45)) – see linked products below.
1 Analogue Input (0-10Vdc, 0-20mA & 4-20mA), 5 Programmable Digital Inputs (PNP/NPN), 1 Pulse Input (10kHz), 1 Analogue Output, 1 Digital Output,Modbus RS485 (RJ45)
1 Relay set of Changeover contacts (Resistive Load 3A/250VAC -5A/30VDC,  Inductive Load 1.2A/250VAC -2A/30VDC)
Common DC Bus Terminals

Safe Torque Off (STO): Functional to SIL2 (EN61800), EN 60204-1 Category 0, EN 62061 SIL CL 2, SO 13849-1:2015 Category 3 PL d.

​Environment and installation:
Pollution degree 2, Indoor use only, Cubicle mount only.
Rated at IP20
Humidity: 90%

Altitude: 0 ~ 1000m for normal operation
Heat Loss at High Overload: 27.3W total at max output

Cooling: Natural, no internal fan.
Ambient operating temperature to 50°C (40°C when units mounted side-by-side)
Ventilation space in front [not specified], above: 50mm, below: 50mm, at sides 30mm.

Certification: CE, UL, RoHS RCM, TUV, REACH, KC.

Manufacturer part number is VFD2A5ME11ANSAA