Astar is your go-to solution for all your AC inverter needs. Our Delta ME300 IP20 0.75kW 115V 1PH to 230V 3PH AC Inverter DBr STO VFD4A8ME11ANSAA is the ultimate equipment for industrial use, boasting superior power and efficiency. And when you need repairs, our team is ready and waiting to assist you. You can’t go wrong with Astar!

Contact us to inquire about this product

If you love this product and wish for a customized quote contact us at number +9190449 0777 and we will be happy to provide you with more info!

Add To Inquiry

Description

Delta ME300 Basic Compact Series AC Inverter for 0.75kW (1HP) 115V/230V 3ph motor to 4,8A at high overload or 0.75kW (1HP) to 5,5A when Fan/Pump rated. Operates in VxF or Sensorless Vector and converts fixed frequency Single Phase 115V input to variable frequency Three Phase 115V to 230V to control a standard AC induction, permanent magnet motor, IPM (Interior permanent magnet) and SPM (surface mounted permanent magnet).

Input Current: 4,8A at High Overload, 5,5A when Fan/Pump rated.
Input Voltage: Single phase AC 100–120 V (-15– +10%), 50/60 Hz.
Output: Variable to 230V Three phase.
EMC: None

Frame Size: C1 87mm Wide x 136mm Deep x 157mm High. IP20.
Mounting via 4 x M5 bolts (not supplied) at rear on 73mm x 144.5mm centres. (Optional DIN-Rail mounting available – see linked products below).
Weight: 0.4kg.

Overload:
150% for 60 seconds. High Overload. (Heavy Duty, HD), 200% of rated output current for 3 seconds.
120% for 60 seconds. Fan/Pump Rated. (Normal Duty, ND), 150% of rated output current for 3 seconds.

Speed Control Range: 0-599Hz. +/- 0.1%.
1 : 50 (V/f, SVC control for IM, heavy duty).
1 : 20 (SVC control for PM, heavy duty).
Switching (Carrier frequency): 2-15 kHz.

Braking (DBr): Built-in braking transistor for 125% Torque x 10 seconds every 100 seconds to 63.3 Ohm minimum external resistor (not supplied). Recommended resistor 200 Ohms 80W – see the Resistor options linked below or use the ‘Which Resistor’ button on this page. (Does not have to be used; available if required)

Product Features: Integrated Operator Keypad with integral potentiometer, (Option external keypad can be connected to the RS485 port (RJ45)) – see linked products below.
1 Analogue Input (0-10Vdc, 0-20mA & 4-20mA), 5 Programmable Digital Inputs (PNP/NPN), 1 Pulse Input (10kHz), 1 Analogue Output, 1 Digital Output,Modbus RS485 (RJ45)
1 Relay set of Changeover contacts (Resistive Load 3A/250VAC -5A/30VDC,  Inductive Load 1.2A/250VAC -2A/30VDC)
Common DC Bus Terminals

Safe Torque Off (STO): Functional to SIL2 (EN61800), EN 60204-1 Category 0, EN 62061 SIL CL 2, SO 13849-1:2015 Category 3 PL d.

​Environment and installation:
Pollution degree 2, Indoor use only, Cubicle mount only.
Rated at IP20
Humidity: 90%

Delta ME300 Basic Compact Series AC Inverter for 0.75kW (1HP) 115V 3ph motor to 4,8A at high overload or 0.75kW (1HP) to 5,5A when Fan/Pump rated. Operates in VxF or Sensorless Vector and converts fixed frequency Single Phase 115V input to variable frequency Three Phase 115V to control a standard AC induction, permanent magnet motor, IPM (Interior permanent magnet) and SPM (surface mounted permanent magnet).

Input Current: 4,8A at High Overload, 5,5A when Fan/Pump rated.
Input Voltage: Single phase AC 100–120 V (-15– +10%), 50/60 Hz.
EMC: None

Frame Size: C1 87mm Wide x 136mm Deep x 157mm High. IP20.
Mounting via 4 x M5 bolts (not supplied) at rear on 73mm x 144.5mm centres. (Optional DIN-Rail mounting available – see linked products below).
Weight: 0.4kg.

Overload:
150% for 60 seconds. High Overload. (Heavy Duty, HD), 200% of rated output current for 3 seconds.
120% for 60 seconds. Fan/Pump Rated. (Normal Duty, ND), 150% of rated output current for 3 seconds.

Speed Control Range: 0-599Hz. +/- 0.1%.
1 : 50 (V/f, SVC control for IM, heavy duty).
1 : 20 (SVC control for PM, heavy duty).
Switching (Carrier frequency): 2-15 kHz.

Braking (DBr): Built-in braking transistor for 125% Torque x 10 seconds every 100 seconds to 63.3 Ohm minimum external resistor (not supplied). Recommended resistor 200 Ohms 80W – see the Resistor options linked below or use the ‘Which Resistor’ button on this page. (Does not have to be used; available if required)

Product Features: Integrated Operator Keypad with integral potentiometer, (Option external keypad can be connected to the RS485 port (RJ45)) – see linked products below.
1 Analogue Input (0-10Vdc, 0-20mA & 4-20mA), 5 Programmable Digital Inputs (PNP/NPN), 1 Pulse Input (10kHz), 1 Analogue Output, 1 Digital Output,Modbus RS485 (RJ45)
1 Relay set of Changeover contacts (Resistive Load 3A/250VAC -5A/30VDC,  Inductive Load 1.2A/250VAC -2A/30VDC)
Common DC Bus Terminals

Safe Torque Off (STO): Functional to SIL2 (EN61800), EN 60204-1 Category 0, EN 62061 SIL CL 2, SO 13849-1:2015 Category 3 PL d.

​Environment and installation:
Pollution degree 2, Indoor use only, Cubicle mount only.
Rated at IP20
Humidity: 90%
Altitude: 0 ~ 1000m for normal operation
Heat Loss at High Overload: 53W total at max output

Cooling: Fan cooling.
Ambient operating temperature to 50°C (40°C when units mounted side-by-side)
Ventilation space in front [not specified], above: 50mm, below: 50mm, at sides 30mm.

Certification: CE, UL, RoHS RCM, TUV, REACH, KC.

Manufacturer part number is VFD4A8ME11ANSAA

Reviews

There are no reviews yet.

Be the first to review “Delta ME300 IP20 0.75kW 115V 1PH to 230V 3PH AC Inverter DBr STO VFD4A8ME11ANSAA Repairing Services”

Your email address will not be published. Required fields are marked *