Did your trusty GC1200 tool suddenly stop working? Don’t worry, our repairing service has got you covered. Our expert technicians will diagnose and fix any issue to make your tool as good as new. We understand the importance of your tools, so we offer prompt and reliable service to get you back to work in no time.
When your GC1200 tool breaks down, it can be a frustrating situation. But with our repairing service, you won’t have to stress about it. We offer a hassle-free and affordable solution to get your tool running like new again. Our team of experts has years of experience, so you know your tool is in good hands. Contact us today to schedule your repair service!
FEATURE:
- Full graphics back-lit LCD display with power save mode
- Supports Auto (AMF, remote start/stop and cyclic modes) and manual modes
- Monitors 1-Ph/3-Ph voltage, frequency and load current for generator and mains; monitors 1-Ph/3-Ph power factor
for generator
- Offers ‘’Auto exercise mode’’ (2 events) to start and stop the genset for preconfigured time
- Monitors engine safety parameters through analog resistive
sensors and digital input switches (e.g. – lube oil pressure, engine temperature, fuel level)
- Controls start relay, fuel relay, stop relay, alarm hooter and more
- Supports the battery charging alternator I/O interface
- MPU interface for engine speed measurement
- Versatile software capable of saving “events” during operation; event log for 100 events with real time clock (RTC) stamps and engine run hour information
- GC1200 has built-in electronic governor module which directly connects to SEDEMAC’s rotary actuators* to guarantee speed governing performance as per ISO8528:G3 class
GC1200 Controller…………………………….. SM0000048
SPECIFICATION:
Environmental Testing Standards
Operating/Storage Temperature
-20˚C to 65˚C/-30˚C to 70˚C, as per IEC 60068-2-1, 2
Vibration
2G in X, Y and Z axes, as per IEC 60068-2-6
Humidity
0% to 95% RH, as per IEC 60068-2-78
EMI/EMC
Compliance as per IEC 61000-6-2, 4
Power Supply
8V – 32V DC continuous; power transients as per ISO 7637 – 2
Ingress Protection
IP65 for front face with optional gasket, as per IEC 60529
Shock
15 g for 11 mS, compliance as per IEC 60068-2-27
Technical
Maximum Standby Current
~0.08A @ 12V or 24V DC
Crank-start Dropout Survival Period
50 mS for a drop from 12V DC
Charging Alternator Interface
0.25A @ 12V DC; 0.125A @ 24V DC
Diagnostic voltage measurement
Digital Output
6 x 0.75A high-side drivers configurable for pre-heat, hooter, etc
Digital Input
5 switch-to-ground inputs configurable for lube oil, temp, fuel level, etc
Analog Input
3 resistive inputs (10Ω – 1000Ω); fully configurable for various sources
1 analog input (2.5V ± 2V) for E-Governor speed bias and paralleling
E-governor Module Interface
Output for rotary actuator
(2.5V ± 2V) input for target speed bias; 2.5V for zero bias
Mains/Genset Voltage Measurement
20V – 350V AC RMS @ 5 – 75 Hz for Ph to N
Load Current Measurement
0A – 5A AC RMS for current transformer (CT) secondary
Magnetic Pickup Measurement
0.2V – 45V @ 10 Hz – 10 kHz
Dimensions
External dimensions: 139 mm x 114 mm x 37.5 mm Mounting panel cut: 118 mm x 93 mm